Welcome to Rayshen Enviromental Pvt Ltd
Need help? +91-94546 03134, +91-8793667336
Enquiry Now
Need help? +91-94546 03134, +91-8793667336
  • Home
  • Biosafety Cabinet

Biosafety Cabinet


BIO Safety Cabinet Ensure maximum protection for operators, laboratory environments, and experimental materials with our advanced Class A2 Biological Safety Cabinet. Engineered to safeguard against infectious aerosols and splashes, this cabinet is ideal for handling primary cultures, bacterial strains, and diagnostic specimens across healthcare, disease control, food safety, biopharmaceuticals, and environmental monitoring sectors.

Key Certifications & Standards

Complies with US NSF/ANSI 49 standards for Class A2 biological safety cabinets.
Meets ISO Class 5 (Class 100) and ISO Class 4 (Class 10) cleanliness levels with patented “Zero-leakage” technology.

Airflow & Filtration

Vertical laminar airflow with negative pressure design.
70% air recirculation after HEPA/ULPA filtration; 30% filtered air discharged or connected to exhaust.
Dual filtration system ensures removal of bacteria, viruses, and airborne particles.

Structural Integrity

Double-walled stainless steel shell with corrosion-resistant, easy-to-clean surfaces.
Negative pressure surround prevents contamination leakage.
Rounded inner chamber corners for enhanced self-cleaning.
Integrated 304 stainless steel reservoir with >4L capacity.

Ergonomic Design

Sliding front window with imported hanging/lifting system and >5mm thick safety glass.
Maintenance-free mechanism allows easy positioning and post-use sterilization.
Adjustable work surface for operator comfort and sample isolation.

Visibility & Monitoring

Built-in internal lighting ensures clear visibility without overheating.
Transparent observation window with manual/automatic switching to minimize external contamination.
LCD interface in with real-time data display and human-machine dialogue system.
Integrated alarm system monitors airflow, filtration status, and system anomalies.

Applications
Perfect for use in:
  • Biological research labs
  • Microbiological operations
  • Healthcare and diagnostics
  • Food and pharmaceutical safety
  • Environmental testing facilities


Key Performance Highlights:
Airflow System: Vertical laminar flow for Class 100 air cleanliness
HEPA Filter Efficiency: 99.95% @ MPPS (compliant with U.S. Federal Standard 209E)
Noise Level: Below 62 dB for quiet operation
Air Volume Range: 990 to 1900 m³/h
Power Supply: Single phase, energy efficient operation
Construction Materials:
Cold rolled steel with electrostatic powder coating
Brushed stainless steel worktops for hygiene and durability
Model Variants:
FSTVC-990 - Compact model for space-sensitive areas
FSTVC-1300 - Mid-size unit with enhanced workspace
FSTVC-1600 - Versatile option for multi process tasks
FSTVC-1900 - High-capacity model for industrial scale applications
Designed for Operator Comfort and Flexibility:
Hemricore clean benches are engineered for minimal vibration and low noise, ensuring a comfortable work environment for extended use. The smartly isolated work area enhances safety and cleanliness. Custom sizes, finishes, and full stainless steel cabinet options are available to suit specific cleanroom layouts and application needs.

Class A2 Biosafety Cabinet – Advanced Protection for Laboratories

The Rayshen Class A2 Biological Safety Cabinet is engineered to deliver powerful operator, product, and environmental protection during microbiological and diagnostic procedures. Designed to contain infectious aerosols, spills, and airborne contaminants, this cabinet is essential for safely handling biological samples, bacterial cultures, tissue work, and sensitive research materials.

Fully compliant with US NSF/ANSI 49 standards and delivering ISO Class 5 / Class 100 clean airflow, this cabinet ensures contamination-free operations using a patented zero-leakage design. Ideal for critical sectors such as healthcare, biotech, disease control, pharmaceuticals, and food safety, the Class A2 Biosafety Cabinet is built for reliability, precision, and long-term laboratory performance.

Key Features of Rayshen Class A2 Biosafety Cabinet

✔ Dual Protection with HEPA/ULPA Filtration

True Class A2 airflow system

70% recirculated air through HEPA/ULPA filter

30% filtered exhaust to environment or ducting

Removes bacteria, viruses, and particulate contamination

✔ Certified Safety & Cleanroom Compliance

Meets NSF/ANSI 49 Class A2 requirements

Delivers ISO Class 5 laminar airflow inside the workspace

Tested for zero leakage and contamination-free operation

✔ Superior Structural Integrity

Double-walled stainless-steel body

Rounded internal corners enhance self-cleaning and disinfection

Negative pressure design prevents accidental leakage

Built-in stainless steel spill reservoir (>4 liters)

✔ Ergonomic, Operator-Friendly Design

Large sliding front sash with >5 mm safety glass

Smooth lifting mechanism for safe positioning

Comfortable working height & noise-reduced airflow

Adjustable working surface for optimized workflow

✔ Intelligent Monitoring & Real-Time Alerts

LCD digital interface with real-time airflow & filter status

Built-in alarm system for airflow deviation, blockage, or operational errors

Internal LED lighting for shadow-free visibility

Observation window with manual/auto mode for contamination control

✔ High-Performance Airflow System

Vertical laminar airflow maintains sterile conditions

Negative pressure ensures harmful aerosols stay contained

Safe for handling infectious microorganisms and biological agents

Technical Specifications

Parameter

Specification

Type

Class II Type A2 Biosafety Cabinet

Certification

US NSF/ANSI 49 compliant

Cleanliness Level

ISO Class 5 / Class 100

Airflow Pattern

70% recirculated, 30% exhaust

Filtration

HEPA/ULPA dual filtration

Body Material

Stainless Steel (double-wall)

Inner Corners

Rounded for easy cleaning

Sash

>5 mm safety glass sliding window

Lighting

Internal LED lighting

Monitoring

LCD interface with alarms

Reservoir

SS spill tray (>4 L)

Operation

Negative pressure, vertical laminar flow

Applications

Microbiology, diagnostics, pharma R&D, biosafety labs

Applications Across Critical Industries

Biological Research & Microbiology

Handling cultures, strains, cell lines

Protection from airborne pathogens

Healthcare & Diagnostics

Sample preparation

Diagnostic specimen handling

Pharmaceutical & Biopharmaceutical Manufacturing

Vaccine R&D

API and biological sample handling

Food & Agriculture Safety

Pathogen testing

Microbial contamination analysis

Environmental Testing Labs

Safe handling of contaminated samples

Water, soil, and environmental microbiology

Model Variants

Standard Class A2 Biosafety Cabinet

Perfect for general microbiology and containment applications.

Advanced Class A2 System with Digital Control

Includes real-time airflow monitoring, filter status display, and enhanced safety alarms.

Custom Biosafety Cabinet

Available with ducting options, ULPA filters, stainless steel upgrades, and custom sizes.

Why Choose Rayshen Biosafety Cabinets?

✔ NSF/ANSI 49 certified safety performance

 ✔ ISO Class 5 laminar flow for sterile operations

 ✔ Dual HEPA/ULPA filtration for maximum protection

 ✔ Zero-leakage patented design

 ✔ Stainless steel construction with rounded edges

 ✔ Intelligent digital monitoring & alarm system

 ✔ Ideal for BSL-2 laboratories and research environments

 ✔ Pan-India delivery, installation & service support

FAQ – Class A2 Biosafety Cabinet

1. What is a Class A2 biosafety cabinet?

It is a biological safety cabinet that provides operator, product, and environmental protection using HEPA-filtered laminar airflow.

2. What level of contamination control does it offer?

It provides ISO Class 5 clean airflow and complies with NSF/ANSI 49 standards.

3. Does it recirculate or exhaust air?

70% of the air is recirculated through HEPA/ULPA filters, and 30% is exhausted.

4. What materials are used for construction?

Double-walled stainless steel for durability and easy cleaning.

5. Can this cabinet be customized?

Yes — models can be designed with ducting, digital control systems, and additional features.

6. Is it suitable for microbiology labs?

Absolutely — it's ideal for all BSL-2 level laboratory applications.

Looking for a certified Class A2 Biosafety Cabinet for your laboratory?

Rayshen delivers advanced, contamination-control biosafety cabinets with reliable filtration, powerful airflow, and international standard compliance.

 📞 Call: +91-8793667336

 📧 Email: info@rayshen.in



All Products